compactTURBOMATIC (“COM”)

Suitable for moderate ambient temperature conditions and applications with low to moderate curing and/or heating requirements.

Main functions

  • Curing with warm water/hot air
  • Aggregate heating with TURBOgas or –steam
  • Generation of warm dosing water

Heating options

  • Heating of batching plant production facilities
  • Generation of warm wash water
  • Supply of warm water for filling of truck mixer saddle tank
PME-COM 300PME-COM 500PME-COM 750

Capacity

300 kW500 kW750 kW
aggregates
45…150 kW

water
105…150 kW
aggregates
75…250 kW

water
175…250 kW
aggregates
115…375 kW

water
260…375 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)
30 l/h50 l/h75 l/h
Natural gas (max rated natural gas flow)
30 m³n/h50 m³n/h75 m³n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)

Options

  • Fully integrated oil tank located inside TURBOcontainer (oil tank volume 4 000 l); separated with fire wall and equipped with all necessary safety etc accessories
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load

Structure / Layout

TURBOcontainer

  • for outdoor usage; equipped with electrical heater
  • standard 20’ (l 6050 x w 2438 x h 2592) container
  • standard colour: RAL 9002

TURBOrack

  • for indoor installation
  • rack dimensions (l 2100 x w 2500 x h 1900); also special rack dimensions as per customer requirements
PME-COM 300

Capacity

300 kW
aggregates 45…150 kWwater 105…150 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)

30 l/h

Natural gas (max rated natural gas flow)

30 m3n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load
PME-COM 500

Capacity

500 kW
aggregates 75…250 kWwater 175…250 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)

50 l/h

Natural gas (max rated natural gas flow)

50 m3n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load
PME-COM 750

Capacity

750 kW
aggregates 115…375 kWwater 260…375 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)

75 l/h

Natural gas (max rated natural gas flow)

75 m3n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load

Options

  • Fully integrated oil tank located inside TURBOcontainer (oil tank volume 4 000 l); separated with fire wall and equipped with all necessary safety etc accessories

Structure / Layout

TURBOcontainer

  • for outdoor usage; equipped with electrical heater
  • standard 20’ (l 6050 x w 2438 x h 2592) container
  • standard colour: RAL 9002

TURBOrack

  • for indoor installation
  • rack dimensions (l 2100 x w 2500 x h 1900); also special rack dimensions as per customer requirements