standardTURBOMATIC ("STD")

Suitable for moderate to severe climate conditions and/or for applications with moderate to high curing and/or heating needs.

Main functions

  • Curing with warm water/hot air
  • Aggregate heating with TURBOgas or –steam
  • Generation of warm dosing water

Heating options

  • Heating of batching plant production facilities
  • Generation of warm wash water
  • Supply of warm water for filling of truck mixer saddle tank
  • Heating of other associated facilities e.g. offices,
    laboratories etc.
  • Production of warm utility water
PME-STD 750PME-STD 1000PME-STD 1250PME-STD 1500PME-STD 2000PME-STD 2500

Capacity

750 kW1000 kW1250 kW1500 kW2000 kW2500 kW
aggregates
75...525 kW

water
675...225 kW
aggregates
100...700 kW

water
900...300 kW
aggregates
125...875 kW

water
1125...375 kW
aggregates
150...1050 kW

water
1350...450 kW
aggregates
200...1400 kW

water
1800...600 kW
aggregates
250...1750 kW

water
2250...750 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)
75 l/h100 l/h125 l/h150 l/h200 l/h250 l/h
Natural gas (max rated natural gas flow)
75 m³n/h100 m³n/h125 m³n/h150 m³n/h200 m³n/h250 m³n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)

Options

  • Full integrated oil tank located inside TURBOcontainer (oil tank volume 4 000 l/20' container or 10 000 l/40' container); separated with fire wall and equipped with all necessary safety etc accessories
  • Combi-burner for dual fuel operation: light fuel oil or gas
  • Gas-burner for propane or other gaseous fuels
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load

Structure / Layout

TURBOcontainer

  • thermally insulated, for outdoor usage
  • side door for easy access
  • standard 20'(l 6050 x w 2438 x h 2592) or 40' (l 12192 x w 2438 x h 2592) container; also special containers as per customer requirements
  • painted as per customer requirements (acc. to RAL-specification)

Rack-mounted

  • for indoor installation
  • rack dimensions (l 5000 x w 2120 x h 2400); also special rack dimensions as per customer requirements
PME-STD 750

Capacity

750 kW
aggregates 75...525 kWwater 675...225 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)

75 l/h

Natural gas (max rated natural gas flow)

75 m3n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load
PME-STD 1000

Capacity

1000 kW
aggregates 100...700 kWwater 900...300 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)

100 l/h

Natural gas (max rated natural gas flow)

100 m3n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load
PME-STD 1250

Capacity

1250 kW
aggregates 125...875 kWwater 1125...375 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)

125 l/h

Natural gas (max rated natural gas flow)

125 m3n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load
PME-STD 1500

Capacity

1500 kW
aggregates 150...1050 kWwater 1350...450 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)

150 l/h

Natural gas (max rated natural gas flow)

150 m3n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load
PME-STD 2000

Capacity

2000 kW
aggregates 200...1400 kWwater 1800...600 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)

200 l/h

Natural gas (max rated natural gas flow)

200 m3n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load
PME-STD 2500

Capacity

2500 kW
aggregates 250...1750 kWwater 2250...750 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)

250 l/h

Natural gas (max rated natural gas flow)

250 m3n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load

Options

  • Full integrated oil tank located inside TURBOcontainer (oil tank volume 4 000 l/20' container or 10 000 l/40' container); separated with fire wall and equipped with all necessary safety etc accessories
  • Combi-burner for dual fuel operation: light fuel oil or gas
  • Gas-burner for propane or other gaseous fuels

Structure / Layout

TURBOcontainer

  • thermally insulated, for outdoor usage
  • side door for easy access
  • standard 20'(l 6050 x w 2438 x h 2592) or 40' (l 12192 x w 2438 x h 2592) container; also special containers as per customer requirements
  • painted as per customer requirements (acc. to RAL-specification)

Rack-mounted

  • for indoor installation
  • rack dimensions (l 5000 x w 2120 x h 2400); also special rack dimensions as per customer requirements