TURBOMATIC Warm Water Unit (“WAT”)

Generation and storage of warm water for curing, heating and utility purposes.

Main function

  • Curing with warm water/hot air
  • Generation of warm dosing water

Heating options

  • Heating of batching plant production facilities
  • Generation of warm wash water
  • Supply of warm water for filling of truck mixer saddle tank
  • Heating of other associated facilities e.g. offices,
    laboratories etc.
  • Production of warm utility water
PME-WAT 300PME-WAT 500PME-WAT 750PME-WAT 1000PME-WAT 1250PME-WAT 1500PME-WAT 2000

Capacity

300 kW500 kW750 kW1000 kW1250 kW1500 kW2000 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)
30 l/h50 l/h75 l/h100 l/h125 l/h150 l/h200 l/h
Natural gas (max rated natural gas flow)
30 m³n/h50 m³n/h75 m³n/h100 m³n/h125 m³n/h150 m³n/h200 m³n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)

Options

  • Fully integrated oil tank located inside TURBOcontainer separated with fire wall and equipped with all necessary safety etc accessories
  • Combi-burner for dual fuel operation: light fuel oil or natural gas
  • Gas-burner for propane or other gaseous fuels
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load

Structure / Layout

TURBOcontainer

 

  • thermally insulated, for outdoor usage
  • side door for easy access
  • standard 20’ (6050 x 2438 x 2592 (L x W x H)) or
  • 40’ (12400 x 2438 x 2592 (L x W x H)) container; also special containers as per customer requirements.
  • painted as per customer requirements (acc. to RAL-specification)

 

TURBOrack

  • for indoor installation
  • rack dimensions (4170–5400 x 2120 x 2400 (L x W x H)); also special rack dimensions as per customer requirements
PME-WAT 300

Capacity

300 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)

30 l/h

Natural gas (max rated natural gas flow)

30 m3n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load
PME-WAT 500

Capacity

500 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)

50 l/h

Natural gas (max rated natural gas flow)

50 m3n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load
PME-WAT 750

Capacity

750 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)

75 l/h

Natural gas (max rated natural gas flow)

75 m3n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load
PME-WAT 1000

Capacity

1000 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)

100 l/h

Natural gas (max rated natural gas flow)

100 m3n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load
PME-WAT 1250

Capacity

1250 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)

125 l/h

Natural gas (max rated natural gas flow)

125 m3n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load
PME-WAT 1500

Capacity

1500 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)

150 l/h

Natural gas (max rated natural gas flow)

150 m3n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load
PME-WAT 2000

Capacity

2000 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)

200 l/h

Natural gas (max rated natural gas flow)

200 m3n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load

Options

  • Fully integrated oil tank located inside TURBOcontainer separated with fire wall and equipped with all necessary safety etc accessories
  • Combi-burner for dual fuel operation: light fuel oil or natural gas
  • Gas-burner for propane or other gaseous fuels

Structure / Layout

TURBOcontainer

 

  • thermally insulated, for outdoor usage
  • side door for easy access
  • standard 20’ (6050 x 2438 x 2592 (L x W x H)) or
  • 40’ (12400 x 2438 x 2592 (L x W x H)) container; also special containers as per customer requirements.
  • painted as per customer requirements (acc. to RAL-specification)

 

TURBOrack

  • for indoor installation
  • rack dimensions (4170–5400 x 2120 x 2400 (L x W x H)); also special rack dimensions as per customer requirements