TURBOMATIC Warm Water Unit (“WAT”)
warm water unit

Generation and storage of warm water for process, heating and utility purposes.

Main function

  • Generation of warm dosing water

Heating options

  • Heating of batching plant production facilities
  • Generation of warm wash water
  • Supply of warm water for filling of truck mixer saddle tank
  • Heating of other associated facilities e.g. offices, laboratories etc.
  • Production of warm utility water
PME-WAT 300PME-WAT 500PME-WAT 750PME-WAT 1000PME-WAT 1250PME-WAT 1500PME-WAT 2000

Capacity

300 kW500 kW750 kW1000 kW1250 kW1500 kW2000 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)
30 l/h50 l/h75 l/h100 l/h125 l/h150 l/h200 l/h
Natural gas (max rated natural gas flow)
30 m³n/h50 m³n/h75 m³n/h100 m³n/h125 m³n/h150 m³n/h200 m³n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)

Options

  • Fully integrated oil tank located inside TURBOcontainer separated with fire wall and equipped with all necessary safety etc accessories
  • Combi-burner for dual fuel operation: light fuel oil or natural gas
  • Gas-burner for propane or other gaseous fuels
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load

Structure / Layout

TURBOcontainer

 

  • thermally insulated, for outdoor usage
  • side door for easy access
  • standard 20’ (6050 x 2438 x 2592 (L x W x H)) or
  • 40’ (12400 x 2438 x 2592 (L x W x H)) container; also special containers as per customer requirements.
  • painted as per customer requirements (acc. to RAL-specification)

 

TURBOrack

  • for indoor installation
  • rack dimensions (4170–5400 x 2120 x 2400 (L x W x H)); also special rack dimensions as per customer requirements
PME-WAT 300

Capacity

300 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)

30 l/h

Natural gas (max rated natural gas flow)

30 m3n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load
PME-WAT 500

Capacity

500 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)

50 l/h

Natural gas (max rated natural gas flow)

50 m3n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load
PME-WAT 750

Capacity

750 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)

75 l/h

Natural gas (max rated natural gas flow)

75 m3n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load
PME-WAT 1000

Capacity

1000 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)

100 l/h

Natural gas (max rated natural gas flow)

100 m3n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load
PME-WAT 1250

Capacity

1250 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)

125 l/h

Natural gas (max rated natural gas flow)

125 m3n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load
PME-WAT 1500

Capacity

1500 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)

150 l/h

Natural gas (max rated natural gas flow)

150 m3n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load
PME-WAT 2000

Capacity

2000 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)

200 l/h

Natural gas (max rated natural gas flow)

200 m3n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load

Options

  • Fully integrated oil tank located inside TURBOcontainer separated with fire wall and equipped with all necessary safety etc accessories
  • Combi-burner for dual fuel operation: light fuel oil or natural gas
  • Gas-burner for propane or other gaseous fuels

Structure / Layout

TURBOcontainer

 

  • thermally insulated, for outdoor usage
  • side door for easy access
  • standard 20’ (6050 x 2438 x 2592 (L x W x H)) or
  • 40’ (12400 x 2438 x 2592 (L x W x H)) container; also special containers as per customer requirements.
  • painted as per customer requirements (acc. to RAL-specification)

 

TURBOrack

  • for indoor installation
  • rack dimensions (4170–5400 x 2120 x 2400 (L x W x H)); also special rack dimensions as per customer requirements

COMBINED HEATING AND COOLING SOLUTION

The TURBOMATIC thermal energy unit can be combined with a COOLMATIC cold or ice water unit to provide a fully-integrated, combined heating & cooling solution.

The COOLMATIC cold and ice water units provide a total cooling solution including all the necessary equipment for the production, storage and dosing of cold or ice water.

When combining the TURBOMATIC with the COOLMATIC cold or ice water unit to form a combined cooling and heating solution, the TURBOMATIC’s hot water tank is utilized for storage of cold water and the same dosing water equipment utilized during cold weather operation to supply the warm dosing water to the water scale/water meter is utilized during warm weather operation to supply cold or ice water.

For more information about the COOLMATIC cooling system please refer to the Cooling Products page.

GO TO COOLING PRODUCTS »