TURBOMATIC TURBOsteam generator (“TSG”)
steam generator

Suitable for extreme climate conditions and when high power, continuous 24/7 heating of aggregates is needed.

Main function

  • Aggregate heating with TURBOgas or –steam
PME-TSG 300PME-TSG 500PME-TSG 750PME-TSG 1000PME TSG-1250PME TSG-1500PME TSG-2000PME-TSG 2500

Capacity

300 kW500 kW750 kW1000 kW1250 kW1500 kW2000 kW2500 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)
30 l/h50 l/h75 l/h100 l/h125 l/h150 l/h200 l/h250 l/h
Natural gas (max rated natural gas flow)
30 m³n/h50 m³n/h75 m³n/h100 m³n/h125 m³n/h150 m³n/h200 m³n/h250 m³n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)

Options

  • Fully integrated oil tank located inside TURBOcontainer separated with fire wall and equipped with all necessary safety etc accessories
  • Combi-burner for dual fuel operation: light fuel oil or natural gas
  • Gas-burner for propane or other gaseous fuels
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load

Structure / Layout

  • thermally insulated, for outdoor usage
  • side door for easy access
  • standard 20’ (l 6050 x w 2438 x h 2592) also special containers as per customer requirements.
  • painted as per customer requirements (acc. to RAL-specification)

TURBOrack

  • for indoor installation
  • rack dimensions (l 5000 x w 2120 x h 2400); also special rack dimensions as per customer requirements
PME-TSG 300

Capacity

300 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)

30 l/h

Natural gas (max rated natural gas flow)

30 m3n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load
PME-TSG 500

Capacity

500 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)

50 l/h

Natural gas (max rated natural gas flow)

50 m3n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load
PME-TSG 750

Capacity

750 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)

75 l/h

Natural gas (max rated natural gas flow)

75 m3n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load
PME-TSG 1000

Capacity

1000 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)

100 l/h

Natural gas (max rated natural gas flow)

100 m3n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load
PME TSG-1250

Capacity

1250 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)

125 l/h

Natural gas (max rated natural gas flow)

125 m3n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load
PME TSG-1500

Capacity

1500 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)

150 l/h

Natural gas (max rated natural gas flow)

150 m3n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load
PME TSG-2000

Capacity

2000 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)

200 l/h

Natural gas (max rated natural gas flow)

200 m3n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load
PME-TSG 2500

Capacity

2500 kW

Powered with

Light fuel oil, biodiesel (max rated oil flow)

250 l/h

Natural gas (max rated natural gas flow)

250 m3n/h
natural gas pressure 2-4 bar (g), min 0,8 bar (g)
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load

Options

  • Fully integrated oil tank located inside TURBOcontainer separated with fire wall and equipped with all necessary safety etc accessories
  • Combi-burner for dual fuel operation: light fuel oil or natural gas
  • Gas-burner for propane or other gaseous fuels

Structure / Layout

  • thermally insulated, for outdoor usage
  • side door for easy access
  • standard 20’ (l 6050 x w 2438 x h 2592) also special containers as per customer requirements.
  • painted as per customer requirements (acc. to RAL-specification)

TURBOrack

  • for indoor installation
  • rack dimensions (l 5000 x w 2120 x h 2400); also special rack dimensions as per customer requirements

COMBINED HEATING AND COOLING SOLUTION

The TURBOMATIC thermal energy unit can be combined with a COOLMATIC cold or ice water unit to provide a fully-integrated, combined heating & cooling solution.

The COOLMATIC cold and ice water units provide a total cooling solution including all the necessary equipment for the production, storage and dosing of cold or ice water.

When combining the TURBOMATIC with the COOLMATIC cold or ice water unit to form a combined cooling and heating solution, the TURBOMATIC’s hot water tank is utilized for storage of cold water and the same dosing water equipment utilized during cold weather operation to supply the warm dosing water to the water scale/water meter is utilized during warm weather operation to supply cold or ice water.

For more information about the COOLMATIC cooling system please refer to the Cooling Products page.

GO TO COOLING PRODUCTS »